Epic Test Code LAB320 International Normalized Ratio (INR)
Performing Location(s)
BMC,CRH,LFH,OCH,FTT,FOX
Limitations
The INR is designed to monitor long-term anticagulant effects. It is not suited to evaluate hemostatic funtion in patients (ie. liver disease, preoperative screening, etc.)
Reference Values
Analyte | Population | Units | Reference Range | High Critical Value |
Prothrombin Time | General population | seconds | 10.1-13.2 | |
INR | General population | none | 0.9-1.2 | >4.4 |
Routine oral anticoagulation | none | 2.0 - 3.0 | >4.4 | |
Mechanical prosthetic heart | none | 2.5 - 3.5 | >4.4 |
Includes
The INR is a calculated parameter requiring a Prothrombin Time. It cannot be ordered alone.
Days of Analysis
All
Additional Information
See entry for "Prothrombin Time"
Methodology
Calculation
Last Updated
22-July-19 BHD