Epic Test Code LAB101011 Anti-IgA Antibody

Additional Codes

ARUP:2003126

Performing Location(s)

ARUP

Ordering Recommendation

Use prior to transfusion or in possible transfusion reactions to determine the presence of anti-IgA antibodies in patients with selective IgA deficiency.

Specimen Type

Serum

Preferred Container

Gold  or Red Top Tube

Minimum Volume

1 mL serum

Test is not performed at ARUP; separate specimens must be submitted when multiple tests are ordered.

Storage Requirements

Refrigerated. 

Specimen Stability

Ambient: 1 week
Refrigerated: 1 week
Frozen: 2 weeks

Transportation Needs

Refrigerated. 

Days of Analysis

Varies

Available STAT

No

Causes for Rejection

Mislabeled or unlabeled specimen.
Less than 50% draw for Vacutainer tubes
 

Turnaround Time

5-12 days once recived into performing lab

Methodolgy

Quantitative Enzyme-Linked Immunosorbent Assay

CPT Code

83520

Last Updated

2-Oct-20