Epic Test Code LAB301 Platelet Count, Automated
Performing Location(s)
BMC,CRH,LFH,HRK,OCH,FTT,FOX,FCC
Specimen Type
Whole Blood
Preferred Container
Lavender Top
Alternate Container
Filled Purple top microtainer
Blood Tube Draw Volume
Min 50% draw volume
Minumum Volume to Submit for Testing
3.0 mL whole blood
- Multiple test can be performed from this volume. For question please contact the lab at 547-3975.
Storage Requirements
Refrigerate up to 24 hours
Transportation Needs
Deliver to the laboratory within 12 hours at room temperature
Causes for Rejection
Mislabeled or unlabeled specimen
Less than 50% draw for Vacutainer tubes
Clotted
Reference Values
Population | Reference Range | High Critical Value | Low Critical Value |
< 12 years old | 140 - 350 x 10³ /uL | > 1,000,000 | < 20,000 |
General (> 12 years old) | 140 - 425 x 10³ /uL | > 1,000,000 | < 20,000 |
Available STAT
Yes
Days of Analysis
All
Additional Information
NOTE: Manual platelet counts (LAB22132) specimens must be received in the laboratory within 1 hours of collection. Contact the laboratory for further information. DO NOT FREEZE or REFRIGERATE .
Methodology
Automated enumeration
CPT Code
85049
Last Updated