Epic Test Code LAB3764 Clozapine, Serum
Additional Codes
MML:CLZ
Useful For
Monitoring patient compliance of clozapine treatment
An aid to achieving desired serum levels
Method Name
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)
Reporting Name
Clozapine, SSpecimen Type
Serum RedOrdering Guidance
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Red top (serum gel/SST are not acceptable)
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Â
1. Collect specimen immediately before next scheduled dose.
2. Within 2 hours of collection, centrifuge and aliquot serum into a plastic vial.
Additional Information: Therapeutic range (trough level) applies to specimens collected immediately prior to next dose.
Blood Tube Draw Volume
Min 50% draw volume
Specimen Minimum Volume
0.6 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum Red | Refrigerated (preferred) | 28 days | |
Frozen | 28 days | ||
Ambient | 7 days |
Reject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Gross icterus | OK |
Clinical Information
Clozapine (Clozaril), a tricyclic dibenzodiazepine, is used for the symptomatic management of psychotic disorders and is considered an atypical antipsychotic drug. It is currently used primarily for the treatment of patients with schizophrenia or schizoaffective disorders who are at risk for recurrent suicidal behavior and who have encountered nonresponse or adverse, intolerable extrapyramidal side effects with more classical antipsychotics (chlorpromazine, haloperidol).
Although clozapine was developed about 30 years ago and the initial results were promising, the development of several fatal cases of agranulocytosis resulted in the discontinued use of this agent. Seizures, orthostatic hypotension, and an increased risk of fatal myocarditis have also been associated with the use of clozapine. The use of clozapine has regained interest for several reasons. Patients who did not respond to treatment with other antipsychotics improved when clozapine was administered. Also, agranulocytosis, which occurs in approximately 1% to 2% of patients, can be controlled with close hematologic monitoring. However, because of the significant risk of agranulocytosis and seizure associated with its use, clozapine should only be used in patients who have failed to respond adequately to treatment with appropriate courses of standard drug treatments, either because of insufficient effectiveness or the inability to achieve an effective dose because of intolerable adverse reactions from those drugs.
Treatment is usually started with dosages of 25 to 75 mg/day with a gradual increase to reach a final dose of 300 to 450 mg/day within approximately 2 weeks of the initiation of treatment. Once the desired effect is achieved, the dose may be gradually decreased to keep the patient on the lowest possible effective dose.
Patients being treated with clozapine should be closely monitored during treatment for adverse reactions. Treatment must include monitoring of white blood cell count and absolute neutrophil count. Clozapine treatment should be discontinued in patients failing to show an acceptable clinical response. In addition, the need for continuing treatment should be periodically reevaluated in patients exhibiting beneficial clinical responses.
Clozapine is metabolized to desmethylated and N-oxide derivatives. The desmethyl metabolite (norclozapine) has only limited activity, and N-oxide metabolite is inactive.
Reference Values
Clozapine
Therapeutic range: 350-600 ng/mL
Norclozapine
Therapeutic range: Not well established
Clozapine + Norclozapine
Therapeutic range: Not well established
Interpretation
The effectiveness of clozapine treatment should be based on clinical response and treatment should be discontinued in patients failing to show an acceptable clinical response.
Cautions
No significant cautionary statements
Day(s) Performed
Monday through Friday
Report Available
3 to 5 daysSpecimen Retention Time
2 weeksPerforming Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
80159
NY State Approved
YesForms
If not ordering electronically, complete, print, and send a Therapeutics Test Request (T831) with the specimen.