Epic Test Code LAB4942 Hypersensitivity Pneumonitis Extended Panel (Farmer's Lung Panel)
Additional Codes
ARUP:0050157
Specimen Type
Serum
Preferred Container
Serum Separator Tube (SST)
Volume Required
Transfer two 2.5 mL aliquots of serum to individual ARUP Standard Transport Tubes
Minimum Volume
1 mL each
Storage Requirements
After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year (avoid repeated freeze/thaw cycles)
Transportation Needs
Refrigerated
Turnaround Time
3-7 days
Performed- SUN-SAT
Cause of Rejection
Plasma. Contaminated, hemolyzed, or severely lipemic specimens
Components
Allergen, Animal, Feather Mix IgE |
Allergen, Interp, Immunocap Score IgE |
A. fumigatus #1 Ab, Precipitin |
A. fumigatus #6 Ab, Precipitin |
A. pullulans Ab, Precipitin |
Pigeon Serum Ab, Precipitin |
M. faeni Ab, Precipitin |
T. vulgaris #1 Ab, Precipitin |
Allergen, Food, Beef IgE |
A. flavus Ab, Precipitin |
A. fumigatus #2 Ab, Precipitin |
A. fumigatus #3 Ab, Precipitin |
S. viridis Ab, Precipitin |
T. candidus Ab, Precipitin |
T. sacchari Ab, Precipitin |
Allergen, Fungi/Mold, Phoma betae IgE |
Allergen, Food, Pork IgE |
Additional Information
Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.
Methodology
Qualitative Immunodiffusion/Quantitative ImmunoCAP® Fluorescent Enzyme Immunoassay
CPT Code
86003 x3; 86005; 86331 x7; 86606 x5
Last Updated
3-Jan-18