Sign in →

Epic Test Code POC1111 PH ARTERIAL iSTAT

Performing Location(s)

BMC,FOX

Specimen Type

Whole Blood, Arterial

Preferred Container

Heparin coated syringe or capillary or Green top tube (prefer Dark Green top tube)

Alternate Container

Unheparinized syringe for POC immediate testing only

Minimum Volume to Submit for Testing

2.0 mL Whole blood

Transportation Needs

Deliver to laboratory at room temp. within 30 minutes.

Do Not send through the pneumatic tube system

Causes for Rejection

Mislabeled or unlabeled specimen

Clotted specimen

Specimen not analyzed within 30 minutes at room temperature or 60 minutes on ice

Specimen contaminated with Room Air (bubbles in syringe or uncapped)

Pneumatic tube transport of green top tubes or syringes

Reference Values

 

Arterial Reference Ranges

Analyte

Units

Population

Reference Range

High Critical Value

Low Critical Value

pH

(none)

All Populations

7.33-7.45

> 7.60

< 7.25

 

 

 

Includes

Measured – pH

 

Days of Analysis

All

Available STAT

Yes

Additional Information

Requisition must indicate source (i.e. venous) and time sample is drawn

 

Testing Site Dependent Information

Methodology

pH - direct potentiometry

 

CPT Code

pH = 82800

 

Last Updated

12-JUL-23 MS